SPEC1FCATIONS
SizeWith Enclosure, 5.69 x 3.94 x 1.87 in(144 4 x 99.9 x 47.5 mm) Without Enclosure: 5.50 x 3 75 x 2.00 inf139.7 x 95.3 x 50.8 mm)
Weight with enclosure)Approximately 5.1 oz (145 g)
Input Voltage 120 VAC, +10%, -15%, 50/60 Hz.
Input Current Drain90 mA RMS maximum (270 mA peak) while sparking. Does not include valve power
Valve Relay Contact Rating 2.5 A (Inrush 5.0 A maximum)
PrepurgeNone. 15 or 30 seconds depending on model Without prepurge there is less than 1 0 second delay before single try for ignition.
Ambient Temperature Limits-40 and +155 deg. F (-40 and +65 deg. C)
Moisture ResistanceEach module is conformal coated to operate to 90% R.H. However, care must be taken to protect module from direct exposure to water.
Tries for IgnitionAvailable in one- or three-try versions
Trial-for-Ignition Periods3 3, 4.7. 6.8. 10.0 or 12.0 seconds, depending on model.
Flame Failure RetryWhen loss of flame occurs after the initial try for ignition, the control system provides one retry on single-try models and two retries on three-try models.
Flame Current 1 microamp minimum
Flame Failure Response Time Within 0.8 second Spark Rate 60 sparks per second (synchronous) Types of Gas Natural, LP, or manufacturedConnections inch quick connect
SensorSingle spark and sense using high voltage spark electrode as the sensing element or remote or local sensing using a separate sensing elementEnclosure (Optional)Gray Noryl fire retardant plasticSpecifications subject to change without notice